Digitronic Digital Cam Switch Unit
Automationsanlagen GmbH CamCon DC190
4.10.1. The DC190 Status LED
The status LED of the CamCon shows the different blinking intervalls of the the device state. This way,
the operation state of the device can be seen without a PC or a terminal.
total time: 3.2 seconds
State
= "OK"
= "Clear..."
= "Pos.Error: 1"
= "Pos.Error: 2"
= "Pos.Error: 3"
= "Pos.Error: 5"
= "Output Error"
= "indicates an error in the EEPROM memory"
See also chapter "8. Error messages and removal of errors (FAQ)" on page 56.
5. Commissioning
Please check the devices wiring before you switch it on. See also chapter "4. Electrical connections"
on page 14 for hints.
Attention: Inductive Reactances always have to be switched with a recovery diode!
Inductors or contactors that are mounted in proximity to the DC190 or the
wiring of which could affect the unit must be switched with RC elements.
The CamCon acknowledges the start-up with a flashing Status LED. After an internal
check-up, the system is booted (e.g. the EEPROMs checksum is determined as is the Flashs). This
procedure takes a few seconds.
The CamCon DC190 can be programmed via the EtherNet TCP/IP interface, the integrated Web
server DigiWEB or a Web-Browser like Internet Explorer or FireFox. It is therefore necessary to know
or set the units correct IP-address.
5.1. Setting the IP-Address
Attention: Any IP address must only be given once within a LAN. If you do not know any free IP,
please necessarily contact your network administrator before you connect the DC190 to
the network.
The factory setting of the devices IP address is 192.168.3.128 / 255.255.255.0.
Should you decide to use another address, take down the MAC address of your CamCon (see type
plate) first (e.g. 00:50:C2:1E:21:6C).
Connect the CamCon with a CAT5 Ethernet Cable with a switch of your
LAN or connect it via a Cross Over Cable with the RJ45 Connector of
your PCs network card. Now open a command prompt (e.g. by typing CMD
in the Run command line in Windows).
Now type the command
"ipconfig" in the command
prompt, to determine your computers IP and subnet
mask.
If no IP address or subnet mask is displayed here or
the IP is displayed as 0.0.0.0, a network connection is
not yet set or set incorrectly. Please contact your
network administrator if necessary.
In our example the IP-address is 192.168.2.41 while the subnet mask is shown as 255.255.255.0. That
would indicate that the DC190s IP must be configured within the range of 192.168.2.1 to
192.168.2.254. It must, nevertheless, not be identical to the IP of the computer itself. You could use,
for example, the IP 192.168.2.128. or similar.