Digi DC-190 Manuel d'instructions Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
Digitronic Digital Cam Switch Unit
Automationsanlagen GmbH CamCon DC190
6.6.2. Measuring offset
Movement - "System" = Rotatory (standard) Movement - "System" = inear
- System: Can be used to select the controlled system: Either rotatory (like packaging
machines, trimmers or eccentric presses) or a linear system like a
positioning unit or a toggle press.
- Offset: The offset is subtracted from the physical actual value, thus giving you the
possibility to shift the zero value.
Note: If the "System" is set to linear and the direction of rotation is set to negative,
the "Offset" value has to be below zero (e.g. -359). See also chapter
"6.6.1.4.1. The Electronic Rotation Direction Switch".
- Start position: Here you can set a start value if your "System" is set to linear. From this
value on the cam values will start.
Hint: You can also use negative values.
- End position: This value changes automatically if the "System" is set to linear and the
"Start position" or the resolution is changed. This value is always the
highest possible programmable cam value and cannot be changed.
Attention: If the start or end value is overrun, the CamCon switches of, displaying an
error message "Pos-Err 3" or "Error: 3".
- Preset value: This value can be used in both the „rotatory as well as in the linear“
condition to set a physical value to a new, preset value by adding an input
(positive edge).
You could e.g. set the preset value to zero to create an external zero signal
which can be used to synchronise a machine.
- Preset input no.: Enter the number of the input that sets the preset value as an actual value
once its triggered by a positive edge.
- Pr. value store typ: This option is used to determine whether a saved preset is tolerant against
power failures.
Using the "RAM" memory loses the preset every time the device is
switched off and on again.
"EEPROM" saving copies the preset from the RAM into the EEPROM
memory to make it robust against power shortages.
Attention: The EEPROM memory should only be used if the preset is rarely triggered and
absolutely necessary, since the number of writing turns into the EEPROM memory is
limited (to about 100000 cycles). After that, the EEPROM is ultimately damaged and
the CamCons programming data is lost.
Note: The Preset Input will be read in in real time from software date 21.5.2002 on.
Therefore it can be synchronised with a machine.
Version from: 19.04.2012 Page: 40