Digi XBee Guide de l'utilisateur Page 45

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 73
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 44
XBee Sensor Adapter
45
Button
press
Network
association
Action
Single Associated If adapter is asleep, wakes unit for 30 seconds.
Sends a Node Identification broadcast transmission.
All devices that receive this transmission will blink their Associate LED rapidly
for 1 second.
All API devices that receive this transmission will send a Node Identification
frame out their UART (universal asynchronous receiver/transmitter) (API ID
0x95).
Unassociated If adapter is asleep, wakes unit for 30 seconds.
Blinks a numeric error code on the Assc LED, indicating the cause of join
failure.
1 blink: Scan found no PANs.
2 blinks: Scan found no valid PANs based on current SC (Scan Channel) and
ID (PAN ID) settings.
3 blinks: Valid Coordinator or Routers found, but they are not allowing joining
(NJ expired).
7 blinks: Node Joining attempt failed.
10 blinks: Coordinator Start attempt failed.
Two Associated Temporarily enables joining on the adapter and the entire ZigBee network for 1
minute (if the XBee module’s NJ command setting is less than 255). If joining is
permanently enabled on a module (NJ = 255), joining remains permanently
enabled, and this button press has no effect.
Four Associated/
Unassociated
Adapter leaves PAN, if associated, and issues a factory reset to restore default
parameters. Default PAN ID is 0x234.
Vue de la page 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 72 73

Commentaires sur ces manuels

Pas de commentaire