Vue de la page 50
set autoconnect
Chapter 2 Command Descriptions 51
set autoconnect
Devices
supported
This command is supported in all Digi Connect Family devices.
Purpose Used to establish an automatic connection (autoconnection) between the
serial port and a remote network destination, and to display current
autoconnect settings.
Required
permissions
To use this command, permissions must be set to one of the following:
For a user to display autoconnect settings for the line on which they are
logged in: “set permissions s-autoconnect=r-self”
For a user to display autoconnect settings for any line:
“set permissions s-autoconnect=read
For a user to display and set the autoconnect settings for the line on
which they are logged in: “set permissions s-autoconnect=rw-self
For a user to display autoconnect settings for any line, and set the
autoconnect settings for the line on which the user is logged in:
“set permissions s-autoconnect=w-self-r
For a user to display and set the autoconnect settings on any line:
“set permissions s-autoconnect=rw”
See "set permissions" on page 86 for details on setting user permissions
for commands.
Syntax Configure autoconnect
set autoconnect [port=range]
[state={on|off}]
[trigger={always|data|dcd|dsr}]
[service={raw|rlogin|ssl|telnet}]
[description={string}]
[ipaddress=ipaddress]
[ipport=ipport]
[connect_on_string=string]
[flush_string={on|off}]
[keepalive={on|off}]
[nodelay=on|off]
Display autoconnect settings
set autoconnect [port=range]